Product features:


Automatic control Automatic exposure
Fully automatic control, one click automatic detection for sample insertion One click automatic exposure, preview experimental results in advance, no need to repeat
To obtain the experimental results


AUTO FOCUS Image management
Automatically focus based on gear position, no need to manually adjust focus The shooting software has builtin image management , which saves multiple To obtain the experimental results experimental results and has functions such as import, export, batch deletion, and has functions such as import, export, batch deletion, and image viewing
Main applications:
It can collect images of protein electrophoresis gel and DNA gel samples for qualitative and quantitative analysis, including nucleic acid observation stained with EB, SYBR Green, SYBR Gold, Texas Red, GelStar, Fluoroscecin, Radiant Red, etc; As well as the imaging of Coomassi Blue, SYPRO Orange and other protein gel dyed with various dyes, such as Kao dye, silver dye and other samples.


Nucleic acid gel imaging Colony count


Protein gel imaging Thin layer plate imaging
Parameters:
Model:GS-500 ▶External computer Model:GS-500Touch ▶Built in computer | Model:GS-800 ▶External computer Model:GS-800Touch ▶Built in computer |
Basic parameters | Basic parameters |
Camera: high-resolution low light USB 3.0 ultra high speed camera | Camera: high-resolution low light USB 3.0 ultra high speed camera |
Resolution ratio:2592×1944 | Resolution ratio:4000×3000 |
Quantum efficiency: QE>65% | Quantum efficiency: QE>69% |
Physical pixels: 5.03 million physical pixels | Physical pixels: 12 million physical pixels |
Image depth : 16 bit (65536 gray scale) | Image depth : 16 bit (65536 gray scale) |
dynamic range: >4.8OD | dynamic range: >4.8OD |
Electric lens: F/1.2 electric autozoom lens | Electric lens: F/1.2 electric autozoom lens |
White light sample board: 25x25cm LED cold light source sample table | White light sample board: 25x25cm LED cold light source sample table |
UV sample stage: Drawer type tube shadowless low background sample stage, wavelength 302nm | UV sample stage: Drawer type tube shadowless low background sample stage, wavelength 302nm |
Auxiliary light source: Bilateral LED reflected white light | Auxiliary light source: Bilateral LED reflected white light |
Glue cutting device: drawer open glue cutting device | Glue cutting device: drawer open glue cutting device |
Receiving filter: standard BP590nm filter | Receiving filter: standard BP590nm filter |
Data transmission: USB3.0 single line control | Data transmission: USB3.0 single line control |